Your location:Home > Events
1f/

Events

HPL COMPACT BOARD Formaldehyde Content Test

Views: 43207/15/2017  

Test item: Formaldehyde content test

Test method: With reference to EN717-1:2004 chamber method, formaldehyde content was detected by UV-VIS spectrophotometer.


Test condition:

Chamber type:1m³stainless steel chamber

Climatic conditions:23℃,45%R.H.

Air exchange rate:1.0 h-1

Loading factor:1.0㎡/m³

Test duration:240 hours

Test result:0.03mg/m³


Note:

1.mg/m³=milligram per cubic meter

2.Detection limit=0.02mg/m³



Changzhou Yaming Wood Industry Company offers a broader range of looks than ever before. Transform spaces with our modern laminates that are as beautiful as they are durable. Mix and match solids, graphic patterns and finishes. Achieve the look you want for any design challenge or budget.

View More(Total0)Comment Lists
No Comment
I want to comment
Content *
Verification Code*